X Series Common Scales | ||||
Standard Model | with Peak Indicator | ‘L’ Model | Application | Standard |
X-A | XP-A | X-AL | Normal rubber & softer plastics | ASTM D 2240 |
X-C | XP-C | X-C1L | Soft rubber, sponge, textile windings | JIS K 7312/Asker C |
X-D | XP-D | X-DL | Hard rubber & plastics | ASTM D 2240 |
X-F | XP-F | — | Urethane foam, non-woven fabric | Asker F |
X Series Special Scales | ||||
Standard Model | with Peak Indicator | ‘L’ Model | Application | Standard |
X-JA | — | X-JAL | Normal rubber & softer plastics | JIS K 6301 |
X-B | — | X-BL | Semi rigid rubber & plastics | ASTM D 2240 |
X-C2 | XP-C2 | X-C2L | Soft rubber & sponge | Asker C2 |
X-CS | — | — | Polystyrene foam | Asker CS |
X-E | XP-EL | X-EL | Soft & cellular rubber | JIS K 6253 |
X Durometer / Hardness Tester
Series X
- High performance and accuracy
- Calibration cert traceable to NIST included
- Optional ISO-17025 calibration available
The Asker Model X Durometer is a precision instrument for measuring the hardness of various types of rubbers and plastics. Durable metal cases are rugged enough for a production environment. X handheld durometers are easy to use. The easy operation allows for rapid testing with repeatable results. The Asker High Performance X series has an accuracy of ±.75 point and is available in Type F for soft materials like sponge rubber and urethane foam. X Model durometers are available in ASTM D 2240 Types: Shore A Hardness, Shore D Hardness, Asker C Hardness, as well as Asker F Hardness. Type F hardness testers use their own weight to determine hardness.
Add ‘P’ to the model number to specify optional peak indicator, for example XP-A. Add ‘L’ to the model number to specify extended presser foot models.
Operation
As the X durometer is pressed against the sample, the material resistance force and indentor spring load balance. The depth of the indentor is measured, which provides a measure of the material’s hardness. Values are based upon a 100 point scale (accuracy ±.75 point). However, as time elapses the indicator will “creep” back so that a reading taken a few seconds after the indentor makes contact with the sample will be less than the peak reading. Asker durometers offer a peak indicator as an option to more closely monitor the difference between peak and “creep”.
What’s Included with the Durometer?
Asker X durometers are sold as kits. All new durometer purchases include: durometer, hard plastic carrying case and 3-Point Calibration certificate traceable to NIST.
X Durometer Selection
Scale | Shore A | Asker C | Shore D | Asker F |
Indentor | Flat point | Hemispherical | Cone point | Rectangular |
Material | Normal rubber | Soft rubber | Hard rubber & plastic | Urethane foam & non-woven fabric |
Standard | ASTM D-2240 | JIS K-7312 | ASTM D-2240 | Asker F |
Measuring Force | 1 kgf | 1 kgf | 5 kgf | Weight of the durometer |